  80 assistance needed? please contact ji a n g ha i euro p e gmbh +49 (0) 2151 652088-72 or info@jianghai-europe.com snap-in 4 000h at 85c miniaturized 85c cd 891 zj series i tem characteristics o perating temperature r ange (c) -40 ~ +85 -25 ~ +85 voltage r ange (v) 35 ~ 400 420 ~ 500 capacitance r ange (f) 68 ~ 15 000 capacitance t olerance (20c, 120hz) 20% leakage current (a) after 5 minutes at 20c application of rated voltage, leakage current is not more than 0,01cv or 1,5ma, whichever is smaller c: nominal capacitance (f) v : rated voltage (v) dissipation factor (20c, 120hz) rated voltage (v) cap (f) 35~50 63 80~100 2 700 0,20 0,15 0,15 3 300 ~ 4 700 0,25 0,20 0,15 5 600 ~ 6 800 0,30 0,20 0,20 8 200 0,35 0,25 - rated voltage(v) ? (mm) 160~200 250~500 22 ~ 30 0,10 0,15 35 0,12 0,15 stability at low temperature ( i mpedance r atio at 120hz) rated voltage (v) 35 50~100 160~200 250~400 420~500 z -25c / z +20c 4 3 4 z -40c / z +20c 15 10 6 8 - u seful life load life endurance t est shelf life lifetime 4 000h > 65 000h 2 000h 3 000h 1 000h leakage current not more than specifed value not more than specifed value not more than specifed value not more than specifed value capacitance change within 30% of initial value within 15% of initial value within 20% of initial value within 15% of initial value dissipation factor not more than 300% of specifed value not more than 150% of specifed value not more than 200% of specifed value not more than 150% of specifed value condition: applied voltage applied current applied temperature o utlier percentage u r i r 85c 1% u r 1,2 x i r 40c 1% u r i r 85c 0% u r i r = 0 85c iec 60384 u r = 0 i r = 0 85c 0% after test: u r to be applied for 30min >24h before measurement frequency r ated voltage (v) 50hz 120hz 1khz 10khz 50khz 50 0,88 1,00 1,15 1,15 1,15 63 ~ 100 0,80 1,00 1,32 1,45 1,50 160 0,80 1,00 1,30 1,41 1,43 multiplier for ripple current frequency coeffcient i a = actual ripple current at 120hz, i r = rated ripple current at 120hz, 85c multiplier of useful life as a function of ambient temperature and ripple current load multiplier for lifetime lifetime diagram u r 160v 45 55 65 75 85 95 cd 891 zj series t a (?c) i a CCC i r 2.0 1.5 1.0 0.5 0.0 lifetime multiplier x16 x8 x4 x2 x1 i a = actual ripple current at 120hz, i r = rated ripple current at 120hz, 85c multiplier of useful life as a function of ambient temperature and ripple current load multiplier for lifetime lifetime diagram u r < 160v 45 55 65 75 85 95 cd 891 zj series t a (?c) i a CCC i r 2.5 2.0 1.5 1.0 0.5 0.0 x16 x8 x4 x2 x1 lifetime multiplier cd 296 kc cd 294 bw cd 295 bc 105c longer life cd 293 bz 105c longer life cd 891 zj miniaturized size
81 assistance needed? please contact ji a n g ha i euro p e gmbh +49 (0) 2151 652088-72 or info@jianghai-europe.com customer specifc products and adaptions on request. snap-in ratings for cd 891 zj series cd 891 zj series u r .dc (surge voltage) code r ated capa- citance max es r 20c, 120hz typ es r 20c, 120hz max r ipple current 85c, 120hz size ? d x l (v) (f) (m) (m) (arms) (mm) 35 (44) 1v 4 700 71 57 2,2 22 x 30 6 800 59 47 2,6 25 x 30 10 000 47 38 3,0 25 x 35 47 38 3,2 30 x 30 47 38 3,0 35 x 20 15 000 31 25 3,3 30 x 35 50 (63) 1h 2 200 120 97 1,6 20 x 25 3 300 100 81 2,0 22 x 30 100 81 2,0 25 x 25 4 700 71 57 2,4 25 x 30 71 57 2,4 30 x 25 10 000 47 38 3,2 25 x 50 63 (79) 1j 3 300 81 65 2,6 25 x 30 4 700 57 46 2,6 22 x 50 57 46 2,6 25 x 35 5 600 48 38 2,7 25 x 40 6 800 40 32 2,9 25 x 50 8 200 41 33 3,5 35 x 35 10 000 34 27 4,0 35 x 40 15 000 23 18 4,4 35 x 50 80 (100) 1k 1 800 111 89 1,9 22 x 30 2 200 90 75 2,0 25 x 30 2 700 74 59 2,6 25 x 35 3 300 61 49 2,7 22 x 45 4 700 43 34 3,3 25 x 55 8 200 32 25 4,2 35 x 50 10 000 28 22 4,5 35 x 50 100 (125) 2a 1 000 230 180 1,5 22 x 30 1 200 166 133 1,6 22 x 30 2 200 91 73 2,2 22 x 55 91 73 2,2 25 x 40 91 73 2,2 30 x 30 4 700 43 34 3,4 30 x 50 200 (250) 2d 120 1 300 1 050 1,0 22 x 25 470 283 226 1,7 25 x 30 680 196 157 2,3 22 x 45 1 000 160 128 2,6 25 x 40 160 128 3,1 30 x 40 1 500 125 1 15 3,7 25 x 50 1 800 120 100 3,7 35 x 40 2 200 100 80 3,8 35 x 45 2 700 90 75 4,0 35 x 55 3 300 60 50 4,2 35 x 60 250 (300) 2e 330 603 483 1,3 22 x 30 680 293 235 2,3 25 x 50 1 000 199 160 3,0 30 x 40 1 500 135 1 10 3,8 30 x 50 1 800 1 10 90 4,4 35 x 45 2 200 90 75 4,6 35 x 50 400 (450) 2g 68 2 926 2 341 0,55 22 x 20 100 1 990 1 592 0,9 25 x 25 120 1658 1 327 0,8 25 x 25 150 1 327 1 062 0,9 22 x 30 220 905 724 1,1 30 x 30 270 737 590 1,3 25 x 40 330 603 483 1,6 22 x 50 603 483 1,6 30 x 40 603 483 1,5 35 x 30 390 51 1 409 1,8 30 x 40 470 424 339 1,8 30 x 45 424 339 2,4 30 x 50 424 339 2,1 35 x 40 560 356 285 2,0 30 x 50 356 285 2,25 35 x 35 356 285 2,3 35 x 40 680 300 240 2,5 35 x 45 820 245 200 2,7 30 x 70 245 200 2,6 35 x 50 1 000 200 160 3,1 35 x 55 200 160 3,2 40 x 60 1 200 165 135 3,5 35 x 80 u r .dc (surge voltage) code r ated capa- citance max es r 20c, 120hz typ es r 20c, 120hz max r ipple current 85c, 120hz size ? d x l (v) (f) (m) (m) (arms) (mm) 420 (470) 2x 100 1 990 1 592 0,7 22 x 35 1 990 1 592 0,7 25 x 30 150 1 330 1 062 0,94 25 x 40 180 1 106 885 1,0 25 x 40 1106 885 1,0 30 x 35 1106 885 1,0 35 x 25 220 905 724 1,1 25 x 45 905 724 1,1 30 x 40 905 724 1,1 35 x 30 270 737 590 1,4 30 x 30 330 603 483 1,7 25 x 50 603 483 1,7 30 x 45 603 483 1,7 35 x 35 470 424 339 2,1 30 x 50 424 339 2,1 35 x 45 680 293 235 2,5 35 x 50 1 000 200 160 3,2 35 x 70 450 (500) 2w 100 1 990 1 592 0,7 22 x 30 1 990 1 592 0,7 25 x 30 150 1 327 1 062 0,9 22 x 40 1327 1062 0,9 25 x 35 220 905 724 1,1 25 x 45 905 724 1,0 30 x 35 905 724 1,0 35 x 30 330 603 483 1,6 30 x 40 603 483 1,6 35 x 35 390 51 1 409 1,8 25 x 55 511 409 1,8 30 x 45 511 409 1,7 35 x 35 470 424 339 2,2 30 x 50 424 339 2,2 35 x 40 560 355 285 2,3 35 x 50 680 395 234 2,3 35 x 50 820 245 195 2,5 35 x 60 1 000 200 160 3,1 35 x 80 1 200 165 135 5,0 40 x 100 1 500 159 120 6,0 40 x 100 1 800 150 115 5,9 45 x 100 2 200 90 75 6,0 45 x 100 500 (550) 2h 470 425 340 2,3 35 x 55 560 400 320 2,35 35 x 60 680 295 234 2,5 35 x 70
8 assistance needed? please contact ji a n gh a i euro pe g mbh +49 (0) 2151 652088-72 or info@jianghai-europe.com part number system order code smd, radial, snap-in dimensions for loose, short cut leads (bulk) order code: cc (cb, cd, ce, cf) straight lead bended lead code cb cc cd ce cf l 5,0 0,5 4,5 0,5 4,0 0,5 3,5 0,5 3,0 0,5 in mm preferred ec r 1c pt 101 m ff 25 0611 je xxxxx technology terminal type rated voltage code series code capacitance code (in f) capacitance tolerance lead form terminal/ pitch size size ? d x l material code rubber type for specials only ec = electrolytric capacitor smd = v 2, 5v = 0e cd 110 = pt 0,47 = r47 20% = m smd: 4x7 = 0407 - = standard - = standard radial = r 4v = 0g cd 11gl = gl 1,0 = 010 10% = k taped = ff terminal = t2 5x11,5 = 0511 v = pcv sleeve f = flat rubber pc = polymer capacitor snap-in = s 6, 3v = 0j cd 261 = lk 2,2 = 2r2 +20 / -0% = r radial: 6,3x11,5 = 0611 e = pet sleeve s = stand-off 10v = 1a cd 261x = qx 10 = 100 +20 / -10% = v taped = ff 2,0mm = 20 35x80 = 3580 16 v = 1c cd 262 = qm 100 = 101 +30 / -10% = q long lead = ll 2,5mm = 25 45x100 = 45100 20 v = 1d cd 263 = bk 1 000 = 102 +50 / -10% = t cut 5,0mm = cb 3,5mm = 35 25 v = 1e cd 269 = ph 10 000 = 103 cut 4,5mm = cc 5,0mm = 50 35 v = 1v cd 269l = hl cut 4,0mm = cd 7,5mm = 75 40 v = 1g cd 281 = ll cut 3,5mm = ce 10,0mm = 10 50 v = 1h cd 281l = lh cut 3,0mm = cf 12,5mm = 12 63 v = 1j cd 287 = gc on request: alternative lead forms (keyed polarity, axial, 90 - angle, others) 80v = 1k cd 28l = ql 100v = 2a cd 293 = bz snap- i n: 160v = 2c cd 294 = bw 4,0mm pin length = t/l4 2 pin = p2 18 0v = 2k cd 295 = bc 6,3mm pin length = t/l6 3 pin = p3 20 0v = 2d cd 296 = kc soldering pin = s4 4 pin = p4 25 0v = 2e cd 297 = bb on request: alternative pin types 5 pin = p5 31 5v = 2f cd 299 = pg 350v = 2v cd 29d = hr 385v = 2j cd 29g = ba preferred 400v = 2 g cd 29h = qh 415v = 2p cd 29l = ql 420v = 2x cd 29u = cu 450v = 2w cd 801 = zp 500v = 2h cd 804 = zm 550v = 2y cd 811 = zn 575v = 2z cd 840 = zq 600v = 2s cd 891 = zj 630v = j2 cd 892 = zl cd 895 = zk polymer on request order code smd, radial, snap-in 2.5max l l 7 l 11 ? d 3 4 5 6,3 8 5 6,3 8 10 12,5 16 18 20 22 25 f 1 1,5 2,0 2,5 3,5 2,0 2,5 3,5 5,0 7,5 10,0 12,5 ? d 0,4 0,45 0,5 0,6 0,8 1,0 a max 1,0 2,0 2,5 for diameter 20 pitch 7,5 on request. in mm dimensions for loose, long-lead type (bulk) order code: ll technical specifcation radial type l
10 assistance needed? please contact ji a n g ha i euro p e gmbh +49 (0) 2151 652088-72 or info@jianghai-europe.com part number system technical specifcation snap-in type 2 pin type: t6p2 / t4p2 standard standard version: self-lock terminal. other terminal types and styles on request. for diameter ?d 45 mm the safety vent is typically placed at the side of the housing. terminal t6 t4 pin length t 6,3 mm preferred 4,0 mm pin detail l 3,5 mm preferred 2,5 mm 3 pin type: t4p3 4 pin type: t6p4 / t4p4 standard standard version: non-lock terminal for ?d 30 mm only. other terminal types and styles on request. for diameter ?d 45 mm the safety vent is typically placed at the side of the housing. terminal t6 t4 pin length t 6,3 mm preferred 4,0 mm pin detail l 3,5 mm preferred 2,5 mm for diameter ?d 45 mm the safety vent is typically placed at the side of the housing.
11 assistance needed? please contact ji a n g ha i euro p e gmbh +49 (0) 2151 652088-72 or info@jianghai-europe.com part number system 4 pin type: l6p4 / l4p4 self-lock terminal for ?d 30 mm only. other terminal types and styles on request. for diameter ?d 45 mm the safety vent is typically placed at the side of the housing. 5 pin type: s4p5 soldering pin for ?d 30 mm only. for diameter ?d 45 mm the safety vent is typically placed at the side of the housing. technical specifcation snap-in type terminal l6 l4 pin length t 6,3 mm preferred 4,0 mm pin detail l 3,5 mm preferred 2,5 mm
14 assistance needed? please contact ji a n g ha i euro p e gmbh +49 (0) 2151 652088-72 or info@jianghai-europe.com life time estimation lifetime estimation of aluminum electrolytic capacitors from jianghai to estimate the lifetime of a non-solid aluminum electrolytic capacitor from jianghai , the following formulas can be utilized. the lifetime depends mainly on the ambient temperature, the ripple current and, within certain limits, the operating voltage applied. other parameters may also affect the lifetime. moreover, l 0 can be interpreted in many different ways, which has a fundamental infuence on the numerical result. jianghai offers a high transparency by publishing the different typical defnitions of lifetimes in each datasheet. lifetime estimations are approximations by nature. please let j i a n gha i e uro pe confrm any result before using it. the formulas given here do not constitute part of a contract nor of a specifcation. the formulas do not cover additional aging effects of certain electrolytic systems or other chemical effects. please contact us should you need lifetime estimates for solid electrolyte polymer capacitors. also the dimensions of the components may have an effect. forced cooling or other additional cooling-methods have a strong impact on the lifetime and are not covered by the formulas. for the estimation and interpretation of lifetime, a close collaboration with j i a n gha i e uro pe is strongly advised. structural formula: l = l 0 k t k r k v where: l t otal lifetime l 0 lifetime under rated ripple current at upper category temperature (see catalogue) k t t emperature factor k r ripple current factor k v v oltage factor 1. k t temperature factor: aluminum electrolytic capacitors f ollow roughly the 10 k rule of arrhenius. it is possible to estimate the lifetime by rule of thumb: when the operational tempe rature is reduced by 10 k, the lifetime will double. the formula for k t in detail is: k t = 2 t 0 - t a 10k where: t 0 rated temperature t a ambient temperature, upper category temperature 2. k r r ipple current factor: the infuence of ripple current on lifetime can be estimated according to the following formula: k r = k i ? t 0 10k ( ) a a = 1 C i a i r 2 with: where: i a actual rated ripple current i r ripple current at upper category temperature (databook value) t 0 core temperature rise of the capacitor (typically 5k for t 0 = 105c and 10k for t 0 = 85c) k i basis, defned as t 0 = 105c i a > i r : k i = 4 i a i r : k i = 2 t 0 = 85c k i = 2
15 assistance needed? please contact ji a n g ha i euro p e gmbh +49 (0) 2151 652088-72 or info@jianghai-europe.com life time estimation 3. k v voltage factor: for radial electrolytic capacitors, this part of the formula has no impact ( k v = 1). but for some bigg er capacitors like snap-in and screw-terminal types with rated voltages above 350v, the operating voltage will af fect their lifetime. it is expressed as follows: ( ) k v = u a u r -n where: u r rated v oltage u a actual operating v oltage n exponent, defned as: 0,5 u a 1 n = 2,5 u r 0 < u a < 0,5 n = 0 u r 4. frequency correction factors: if the actual ripple currents are not given at the same frequency like i 0 , weighing f actors need to be applied. i a actual rated ripple current (normalized) i f1 ... i fn ripple currents at dif ferent frequencies f f1 ... f fn frequency correction factors for different frequencies i a = ( i f 1 ) 2 + f f 1 ( i f 2 ) 2 + f f 2 ... ( i f n ) 2 f f n l = l 0 k t k r k v 5. j i a n gha i electrolytic capacitor lifetime estimation formula t 0 -t a [ 1- ( i a ) 2 ] ? t 0 u a = l 0 2 10k k i i r 10k ( ) -n u r t 0 = 105c i a > i r k i = 4 i a i r k i = 2 t 0 = 85c k i = 2 0,5 u a 1 n = 2, 5 u r 0 < u a < 0,5 n = 0 u r
109 assistance needed? please contact ji a n g ha i euro p e gmbh +49 (0) 2151 652088-72 or info@jianghai-europe.com handling precautions warranty: the information contained in this catalogue does not form part of any quotation or contract, is believed to be accurate, reliable and up to date. quality data are based on the statistical evaluations of a large quantity of parts and do not constitute a guarantee in a legal sense. however, agreement on these specifcations does not mean that the customer may not claim for replacement of individual defective capacitors within the terms of delivery. we cannot assume any liability beyond the replacement of defective components. this applies in particular to any further consequences of component failure. furthermore it must be taken into consideration that the fgures stated for lifetime, failure rates and outlier percentages refer to the average production status and are therefore to be understood as mean values (statistic expectations) for a large number of delivery lots of identical capacitors. these fgures are based on application experience and data obtained from preceding tests under normal conditions, or C for purpose of accelerated aging C more severe conditions. jianghai reserves the right to change these specifcations without prior notice. any application information given is advisory and does not form part of any specifcation. the products are not primarily designed for use in life support applications, devices or systems where malfunction of these products can reasonably be expected to result in personal injury. jianghai customers using or selling these products for use in such applications without prior written consent of jianghai do so at their own risk and agree fully to indemnify jianghai for any damage resulting from such improper use or sale. this version of the catalogue supersedes all previous versions. latest versions of datasheets can be found on our homepage: www.jianghai-europe.com for more details on precautions and guidelines for aluminum electrolytic capacitors, please refer to cenelec technical report clc/tr 50454:2008 e, guide for the application of aluminum electrolytic capacitors. polarity: electrolytic capacitors are polar and shall never be used with incorrect polarity, as there is a possible danger of shorting or destruction. r ated voltage u r: the rated voltage is marked on the capacitor and defned in the datasheets as ur. this voltage should never be exceeded and is the maximum peak voltage including any ripple voltages allowed to avoid a shortening of the lifetime or damage of the capacitor. when a ripple current is applied to the capacitor, the sum of the peak ripple voltage and bias dc voltage shall never exceed the rated voltage. it might be necessary to lower the maximum allowed bias dc voltage, when certain ripple currents are applied to the capacitor. surge voltage: maximum voltage, which may be applied to the capacitor for short periods of time: max. 1000 cycles of 30 sec. per 6 min., max. 5 pulses per hour. capacitance drift +/- 15% max. r everse voltage: reverse voltages or voltages < 0 v are not allowed. r ec overy voltage: after charging and discharging a capacitor there might still be a voltage between the terminals, which is built up internally due to dielectric absorption. please take action that this load does not damage other devices or scare the workers during production (sparks possible). temperature r a nge: use electrolytic capacitors only within the specifed operating temperature range. o ver-current: currents exceeding the rated ripple currents should be avoided. r i pple current/voltage: the combined value of dc voltage and peak ac voltage (due to ripple current) shall not exceed the rated voltage and shall never be < 0 v. use of aluminum electrolytic capacitors under ripple current with wide amplitudes is equivalent to quick charge-discharge operation. r a pid charging/discharging: rapid charging/discharging generates severe heat and gas may be emitted which may lead to explosion. consult jianghai about specially designed capacitors suitable for such kind of applications. balancing resistors: balancing resistors should be utilized if capacitors are used in serial connection. please choose low-tolerance resistors to limit voltage drift. charge-discharge proof: jianghai capacitors are charge-discharge proof, which means that 10 6 switching cycles will cause capacitance reduction of less than 10%. lifetime: there are many different lifetime defnitions known without any true standard defnition. take special care when capacitors are compared that the capacitors fulfll the needed requirements. jianghai publishes all conditions to be as transparent as possible. in the case of lifetime tests with additional ripple currents, the bias dc voltage must be reduced, so that the sum of bias dc voltage and the peak of the ripple voltage does not exceed the rated voltage ur. ? load life: period of time, during which the technical parameters of all capacitors stay within the given limits. jianghai defnes this without allo wing for outliers. ? u seful life: defned like load life, but a given percentage of components may be o utside the defned limits. useful life data are usually calculated within a confdence level of 60%. see further details in specifcations and data she ets. outlier percentage: 1%. ? endurance t est: iec 60384-4 defnes the acceptable drift criteria of electrical parameters after the endurance tests (continuous voltage test). ? shelf life: defnition of time with acceptable drift of capacitor parameters after storage at upper category temperature without load. jis-c-5102- 1994 vibration and mechanical stress: capacitors are sensitive to vibration and mechanical forces applied on the leads. do not use capacitors, which have been dropped onto a rigid surface. i nsulation: if any defect of the sleeve is visible, the component should not be used C same for any kind of visible damage. a capacitor should be electrically isolated from the following parts: aluminum case, cathode lead wire, anode lead wire and circuit pattern, and auxiliary terminal of snap-in type. the pvc sleeve is not recognized as an isolator and therefore the standard capacitor should not be used in a place where insulation function is needed. please contact jianghai if higher grade of insulation is required. environmental conditions: ? a void direct contact with water, salt solution, oil, dewing conditions ? halogens generally , especially fumigation treatment with bromides and fame retardent agents containing halogens must be avoided. ? a void exposing to direct sunshine, ozone, ultraviolet rays and x-ray radiation. ? air pressure: max. 150kpa, min. 8kpa. ? no heavy air pressure changes are allowed. ? do not use or store in an environment containing any hazardous gas (e.g., hydrogen sulphide, sulphurous acid, nitrous acid, chlorine, amm onia, bromine, methyl bromide, other halogens) or acidic or alkaline solutions . storage: ? t emperature 5 to 30c, humidity below 75%. ? electrolytic capacitors may accumulate charge naturally during storage. in this case discharge through a 1kohm resistor before use (recovery v oltage). ? leakage current may be increased after long storage time. in th is case the capacitor should be subjected to the rated voltage treatment th rough a 1kohm resistor before use for 1 hour , then it should be discharged through a resistor of about 1 ohm/v olt. ? storage times above 1 year should be avoided or rated voltage t reatment may be necessary . ? in accordance to iec 60384-4 electrolytic capacitors are subjec t to a reforming process before acceptance testing. rated voltage is applied via a series resistance (100 : ur 100vdc, 1k: ur > 100vdc). soldering: soldering conditions (temperature, times) should be within specified conditions, especially for smd components. avoid high soldering temperatures as this may reduce lifetime or damage the capacitor. do never dip the capacitor body into molten solder. flux should not be adhered to the capacitors body but only to its terminals. for details and different methods please contact us. cleaning and coating: do not use fxing agents or cleaning substances containing halogens and the epoxy resin coating materials. also never use solvents containing: halogenated hydrocarbons, alkali, petroleum, trichloroethylene/-ethane, xylene, acetones, trichlorotrifuoroethane, tetrachloroethylene, methylenechloride, chloroform, acetates, ketones, esters, chlorides and bromides. in case of questions see detailed instructions. mounting: other devices, which are mounted near the capacitor, should not touch the capacitor. additional heat coming from other components near the capacitor may reduce the lifetime of the capacitor. do never bend or twist the capacitor after soldering to avoid stress on the leads. radial capacitors are not protected against mechanical forces on the leads. forces on the pins might damage the capacitor. no printed circuit board tracks are allowed between the lead pads of the capacitor. screw terminal capacitors should only be mounted in an upright position. transport: avoid fumigation and spraying insecticides (especially with bromides) in the import or export procedures which can cause corrosion. this applies also to the fnished devices. maintenance: periodical inspection should be carried out for the capacitor: visual inspection to check pressure relief open or leakage of electrolyte, electrical characteristics as leakage current, capacitance, and dissipatio n factor. electrolyte and separator paper: electrolyte and separator paper used in aluminum capacitors may be fammable. also electrolyte is electrically conductive. therefore in case electrolyte gets in contact with pc board it may cause corrosion of circuit pattern or cause short circuit between patterns, and may lead to smoke generation or ignition in worst case. caution during u s e of capacitors: do not touch the terminals of capacitors. keep the capacitor free from conductive solution, such as acids, alkali and so on. ensure that the operating environment of the equipment into which the capacitor has been built is within the specifed conditions mentioned in the catalogue or specifcation sheets. safety vent: the safety vent needs some free space to open properly. allow for free headroom of at least 2mm for diameter 16mm, more than 3mm for diameter 18-35mm, more than 5mm for case diameter 40mm and larger. emergency actions: when the pressure relief vent is open and some gas blows out from the capacitor, please turn the main switch of the equipment off or pull out the plug from the power outlet immediately. during safety vent operation, extremely hot gas (>100c) may blow out of the capacitors. do not stand close to the capacitors. in case of eye contact, rinse the open eye(s) with clean water immediately. in case of ingestion, gargle with water immediately, do not swallow. do not touch electrolyte but wash skin with soap and water in case of skin contact. definition of electrical parameters: separate documents as application notes, equivalent circuit diagrams and so on are available on request. packaging: please refer to the data book for details. further information is available on request. jianghai europe electronic components gmbh jianghai electrolytic capacitors v0712